4575 TURBOFLAME BURNERS are particularly applicable to
aluminium melters, ladle heaters, soaking pits, rotary kilns, heat treat furnaces, and dryers. Any installation
where high velocity entertainment, penetration, and recirculation can benefit temperature uniformity and thermal
efficiency. A 4575 TURBOFLAME burner’s true high velocity results from exceptionally high Btu/hr input rates relative
to its reduced tile discharge area. velocities ranging from 500 to 750 feet per second (340 to 510 mph) drive heat
into a furnace load, creating tremendous momentum while entraining and recirculating 7-10 cubic feet of furnace
gases for every cubic foot of burner product. TURBOFLAME are suitable for furnace 0 0 temperatures up to 2400 F.
They can be used with preheated air upto 600 F. The reduced tile discharge opening also protects burner internals
from radiant heat and from melting furnace splash. Standard burners include 3000 F dense castable tiles. o Burner
tile installation should be made in accord with instructions on Supplement DF-M1 for hard refractory lined furnaces
or DF-M2 for fiber lined furnaces.
The TURBOFLAME burners can be used with a variety of control systems including pressure balanced or electronic
fuel/air systems.
The gas pressure requirement is approximately 0.7 that of the combustion air when firing on stoichiometric ratio.
System pressure drops should be checked to make sure that adequate gas pressure will be available at the burner. It
is imperative that the limiting orifice gas valve be placed within 5 pipe diameters of the burner gas connection.
TURBOFLAME burners are not designed for fuel rich operation. Prolonged fuel rich operation may damage the burner.
IGNITION/ SUPERVISION: A gas pilot is preferred. Direct spark
ignition is satisfactory. Torch lighting is not recommended because of high tile pressure. 4575 burners (except the
-8-A and -14 sizes) are available in dual-fuel (gas/light oil) models. TURBOFLAME are an extension upward of
WESMAN’s line of HIGH VELOCITY TYPHOON FLAME GAS BURNERS. For capacities less than 3, 000, 000 Btu/hr, consider 4441
Burners.
FLAME SUPERVISION: UV only, Same rods not
recommended.
| MODEL | COMBUSTION AIR CAPACITIES, scfh FOR Btu/ hr (MULTIPLY BY 100) |
FLAME LENGTH (stoichiometric ratio, 16 osi air) |
||||
|---|---|---|---|---|---|---|
| combustion air pressure drop across the burner in osi | ||||||
| mbar | 0.2 | 1 | 4 | 9 | 16 | |
| TURBOFLAME 4575-8-A | 4400 | 9400 | 19600 | 31000 | 41500 | 5′ |
| TURBOFLAME 4575-8-B | 5250 | 13300 | 29500 | 43600 | 62000 | 6′ |
| TURBOFLAME 4575-9 | 9200 | 21000 | 44000 | 64000 | 89000 | 9′ |
| TURBOFLAME 4575-10-A | 10600 | 23800 | 47600 | 72500 | 101000 | 9′ |
| TURBOFLAME 4575-10-B | 12500 | 28000 | 57500 | 85000 | 119000 | 10′ |
| TURBOFLAME 4575-12 | 19100 | 42700 | 81500 | 118000 | 164000 | 10′ |
| TURBOFLAME 4575-14 | 34000 | 64000 | 124000 | 188000 | 250000 | 17′ |
| MODEL | MAXIMUM EXCESS AIR RATES IN % | AIR CAPACITIES NOT BURNING, scfh (use to size blowers) |
PILOT SET |
DIRECT SPARK IGNITER |
APPROX. NET WEIGHT POUNDS |
||
|---|---|---|---|---|---|---|---|
| COMBUSTION AIR PRESSURE, osi | |||||||
| mbar | 1 | 9 | 16 | 16 osi | |||
| TURBOFLAME 4575-8-A | 325 | 400 | 350 | 55000 | 4011-12 | 4055-E | 195 |
| TURBOFLAME 4575-8-B | 650 | 500 | 750 | 81000 | 4011-12 | 4055-E | 195 |
| TURBOFLAME 4575-9 | 800 | 900 | 1200 | 116000 | 4011-12 | 4055-E | 200 |
| TURBOFLAME 4575-10-A | 675 | 800 | 900 | 145000 | 4011-12 | 4055-E | 280 |
| TURBOFLAME 4575-10-B | 1100 | 1300 | 1200 | 177000 | 4011-12 | 4055-E | 280 |
| TURBOFLAME 4575-12 | 1500 | 1200 | 1000 | 199000 | 4011-12 | 4055-E | 280 |
| TURBOFLAME 4575-14 | 1200 | 1200 | 1200 | 303000 | 4011-12 | 4055-E | 695 |


| MODEL | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mbar | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R | S | T |
| TURBOFLAME 4575-8-A | 6 | 2½ | 3¾ | 5¼ | 7½ | 18 | 16 | 4 1⁄16 | 14 | 9½ | 16⅝ | 9 | 38⅝ | 22½ | 9⁄16 | 8 | 7⅞ | 9 |
| TURBOFLAME 4575-8-B | 6 | 2½ | 3¾ | 5¼ | 7½ | 18 | 16 | 4⅛ | 14 | 9½ | 16⅝ | 9 | 38⅝ | 22½ | 9⁄16 | 8 | 7⅞ | 9 |
| TURBOFLAME 4575-9 | 8 | 2½ | 3¾ | 5¼ | 7½ | 18 | 16 | 5 5⁄16 | 14 | 9½ | 16⅝ | 9 | 38⅝ | 22½ | 9⁄16 | 8 | 10 | 11 |
| TURBOFLAME 4575-10-A | 10 | 3 | 4¾ | 6¼ | 10½ | 22 | 20 | 6¼ | 18 | 11 1⁄16 | 20⅝ | 12 | 47⅜ | 15 | ¾ | 12 | 12¼ | 14 |
| TURBOFLAME 4575-10-B | 10 | 3 | 4¾ | 6¼ | 10½ | 22 | 20 | 6½ | 18 | 11 1⁄16 | 20⅝ | 12 | 47⅜ | 15 | ¾ | 12 | 12¼ | 14 |
| TURBOFLAME 4575-12 | 12 | 3 | 4¾ | 6¼ | 10½ | 22 | 20 | 7 | 18 | 11 1⁄16 | 20⅝ | 12 | 47⅜ | 15 | ¾ | 12 | 14¼ | 16 |
| TURBOFLAME 4575-14 | 14 | 6 | 12 5⁄16 | 8¼ | 12 | 26 | 24 | 9¾ | 22 | 16 | 24⅜ | 18 | 64 | 15 | ¾ | 12 | 16¼ | 18 |
*Air inlets of burners are in BSP thread
REQUEST A QUOTE