Premix Gas Burner

PREMIX GAS BURNER

SERIES 4659

WESMAN 4659 premix gas burners have cast iron mounting gas nozzle and refractory block.

On upstream of these burners, WESMAN 3065 Aspirator air-gas mixers are used. Mixtures of gas and air is supplied to these burners. WESMAN 7218 Air/Gas ratiomatic valve can be used to feed gas to Aspirator mixer.

 

COMBUSTION AIR CAPACITIES m3/h
(for kcal/ hr multiply m3/h by 880)
Mixture pressure in mm of water
MODEL 175 200 300
4659-0-A 15 16 19
4659-0-B 19 20 24
4659-0-C 21 23 28
4659-1-A 26 28 34
4659-1-B 33 35 43
4659-2-A 42 45 55
4659-2-B 49 52 63
4659-2-C 58 62 76
4659-2-D 66 70 86
4659-3-A 73 78 96
4659-3-B 90 96 117
4659-4-A 112 120 146
4659-4-B 142 152 186
4659-4-C 153 164 200
4659-5-A 184 195 239
4659-5-B 217 232 283
4659-6-A 239 255 312
4659-6-B 289 306 374
4659-6-C 317 340 414
4659-7-A 357 380 482
4659-7-B 448 479 584
4659-7-C 527 561 686

Here, vent of 7218 is kept open to atmosphere so that it can work as a Zero governor. If furnace pressure is not same as atmosphere, then furnace chamber is connected with vent of 7218 so that it can regulate as per furnace pressure.

APPLICATIONS: Wire patenting, tunnel kiln and other furnaces where controlled atmosphere is needed.

The burner mounting plate includes holes for pilot or spark ignitor, observation port and flame detector.

DIMENSION
IN (MM)
RECOMMENDED
PILOT
MODEL A B C Wt. KG
4659-1-A, -1-B 25 175 203 18

4021-13
or
4021-14
4659-2-A, -2-B, -2-C, -2-D 32 175 203 18
4659-3-A, -3-B 40 190 225 23
4659-4-A, -4-B, -4-C 50 190 225 23
4659-5-A, -5-B 65 225 225 34

4021-15
or
4021-16
4659-6-A, -6-B, -6-C 75 225 225 34
4659-7-A, -7-B, -7-C 100 225 275 42
Burner Diagram
REQUEST A QUOTE