FireStorm Dual Fuel Burners

SERIES 6514

6514 FireStorm DUAL FUEL BURNERS are suitable for light as well as
heavy oil and all types of gases. It has sealed in CI mounting having provision for UV head, Pilot burner flame
observation parts. These are used for Low as well as high temperature application where long flame is desirable. For
fuel saving, preheated combustion air upto 350 C can be used. In case of using hot combustion air, consult WESMAN for
burner selection.

APPLICATION Ferrous/ Non ferrous melting, steel reheating, Hot air
generator, Laddle preheating, chemical processing, sand drying ovens and many more types of applications. The sealed
mounting stops unwanted air from the atmosphere to enter the burner, which helps to maintain furnace pressure,
controlled atmosphere and better air/ fuel ratio which causes improved product quality. Wesman FireStorm burners are
stable with 100% or more excess air, Good turn down ratio can be achieved depending on grade of oil and also burner
size.
Heavy oil is to be preheated to its viscosity 20.7 centistokes.

TILE JACKET Wesman FireStorm burners are available with SS jackets
to support refractory block for applications where the tile is not supported by furnace refractory.

IGNITION/ FLAME SUPERVISION Wesman pilot burner can be used for
auto ignition. Pilot operation should be interrupted after few seconds. A UV cell will monitor pilot or main flame.
Direct spark ignition can be used while firing only gas as fuel.

AUTO CONTROL It is possible with Air/ oil or Air/ Gas ratio
regulator. Mass flow control is also possible.


TABLE 1: MAIN AIR CAPACITIES


MODEL

COMBUSTION
AIR (m3/hr
@ 70 mbar)

ATOMIZING
AIR (m3/hr
@ 100 mbar)

OIL GAS (NG)
(LPH)-m3/hr

SENSOMATIC
OIL VALVE
MODEL

PILOT TIP
MODEL

FLAME LENGTH
(m) @ 70mbar
COMB. AIR

APPROX
WEIGHT (Kg)

FireStorm
6514-6
422 100 46-51 1813-02C 4021-12 1.5 75

FireStorm
6514-7
691 133 72-80 1813-02D 4025-0-T 2.0 98

FireStorm
6514-8A
1200 215 125-138 1813-02D 4025-0-T 3.0 136

FireStorm
6514-8B
1982 374 208-231 1813-02D 4025-0-T 4 186

FireStorm
6514-9
4135 612 420-467 1813-01 4025-2-T 5.5 321

FireStorm
6514-10
6174 967 630-700 1813-01 4025-2-T 6 450

For Kcal/hr, multiply total air (combustion air
+ atomizing air) by 880
Capacities can be increased up to 30%. Consult WESMAN


TABLE 2: DIMENSION IN (MM)


MODEL

A

B

C

D

E

F

G

FIRESTORM 6514-6
493 381 225 75 40 592 50

FIRESTORM 6514-7
518 406 225 100 50 648 65

FIRESTORM 6514-8A
568 452 250 150 65 814 65

FIRESTORM 6514-8B
618 482 325 150 75 913 75

FIRESTORM 6514-9
708 584 337 200 100 1122 100

FIRESTORM 6514-10
825 698 336 250 150 1284 150


Diagram

REQUEST A QUOTE