CAE · CFD · FEA — ANSYS MECHANICAL & FLUENT
Prove the design in simulation — before you cut steel.
We deliver structural, fluid, thermal and combustion simulation for automotive, industrial fan and thermal-systems manufacturers — from CAD clean-up and meshing to a correlated, decision-ready engineering report.
01 — WHAT WE DO
Simulation expertise across fluids, structures and heat.
02 — INDUSTRIES
Where our simulation work is applied
Automotive R&D
Strength, NVH, CFD and crashworthiness development for components and systems.
Turbomachinery
Centrifugal blower performance, aero-acoustics, rotor fatigue and resonance avoidance.
Furnaces & Thermal Systems
Burners, hot air generators, combustion chambers, refractory and insulation design.
Industrial & Process Equipment
Pipelines, heaters, vessels and thermal-fluid systems under structural and flow loading.
03 — HOW WE WORK
A closed loop from CAD to release
Every simulation is tied back to physical test before a decision is made. If targets are not met, results feed straight into design modification and the loop repeats until the design is validated.
De-feature CAD and build a quality, solver-ready mesh.
Boundary conditions, materials, physics models and solver initialisation.
Contour, vector, animation and 2D result plots that explain the physics.
Compare results against physical test data and calibrate the model.
Recommend a design change, or release with confidence for production.
04 — CASE STUDIES
Recent FEA and CFD applications
A selection of recently delivered studies on flow, turbulence, combustion, thermal and structural problems — each ending in a concrete engineering recommendation.
FEATURED · DECARBONISATION
Natural gas – hydrogen blend combustion CFD for a hot air generator burner
Can an existing burner run on hydrogen-enriched natural gas without new hardware? We compared pure natural gas against an NG + 20% H₂ blend (mole basis) at baseline, +5° and −5° nozzle angles, using non-premixed combustion CFD with full species transport.
- 5 configurations solved to steady state and compared on flame shape, outlet temperature uniformity and thermal efficiency
- Fuel mixture: H₂ 20% · CH₄ 72% · C₂H₆ 4% · C₃H₈ 1.6% · C₄H₁₀ 0.8% · CO₂ 1.6%
- Baseline firing: 0.1219 kg/s blended fuel, 2.433 kg/s combustion air, 18.05 kg/s dilution air at 27 °C
Outcome: NG + 20% H2 at the baseline nozzle recommended — the highest efficiency and lower CO2 intensity, on the existing burner.
Centrifugal blower — performance & noise
Transient CFD to predict and improve pressure, velocity and volumetric efficiency, with aero-acoustic simulation and microphone FFT to locate noise sources — all validated against test data before release.
Outcome: significantly improved P-V performance and a validated geometry with reduced noise signature, ahead of physical prototyping.
Oil-filling simulation of a heater assembly
Volume-of-Fluid modelling of oil filling and air displacement, tracking free-surface evolution, turbulence and the transient force on the heater wall through the complete fill cycle.
Outcome: peak transient wall loading identified early, with design recommendations that prevented a structural failure mode in production.
Hot air generator — combustion & refractory
Non-premixed combustion and radiation modelling to predict temperature distribution and pressure drop along the duct, plus thermal and structural integrity checks of the pressure boundary.
Outcome: an optimised refractory layup that holds the outer shell within safe touch-temperature limits.
Structural integrity of rotating fan components
Static, fatigue and durability assessment, modal and harmonic (FRF) response to avoid resonance, bi-axiality and alternating-stress evaluation, and coupled thermal-stress analysis for insulation design.
Outcome: fatigue-critical zones identified and the design iterated before tooling commitment.
Porous inlet liner for aerodynamic noise
Steady and transient CFD of 15–45 mm Rockwool liners upstream of a blower inlet, using RMS pressure fluctuation at blade tip and outlet as a proxy for noise-source strength.
Outcome: a 30–40 mm “sweet spot” recommended — strong attenuation without the turbulence and pressure-loss penalty seen at 45 mm.
Facing a similar flow, thermal or structural problem?
Share your geometry and targets. We will scope the physics, the model and the deliverables — and tell you what simulation can and cannot answer.
Start a conversation05 — WHY CLIENTS WORK WITH US
Value delivered through simulation-led engineering
Fewer prototypes
Designs are validated virtually first, cutting development time and physical prototype cost.
Faster iterations
Standardised, automated workflows give rapid turnaround on every design change.
Higher reliability
Fatigue, modal and thermal validation improve product performance and service life.
Lower programme cost
Problems are found and fixed in the model, ahead of tooling commitment.
06 — TOOLS
Industry-standard solvers and pre-processors
One partner from model build to final report
- Scoped study plan with physics, assumptions and acceptance criteria
- Meshed (current mesh capacity up to 1 million elements) solved and debugged simulation model
- Post-processed results: contours, vectors, animations and 2D plots
- Test correlation and a clear design recommendation
- Engineering report ready for design review
Let’s build the next design together.
Talk to our engineering team about static structural, vibration, fatigue, strength, flow, thermal, turbulence or combustion problems — or about the right validation approach for your product.